Next Generation 9100, 9500, 9700 Treadmill Diagnostics Information
Entering Diagnostics Menu
for Lifestride Nextgen 9100, 9500, 9700
1. Press and hold PAUSE. While holding PAUSE press CLEAR twice. Continue
to hold PAUSE until the display reads "SERVICE MENU."
2. Press any UP ARROW and select "SYSTEM TEST, INFORMATION,
MAINTENANCE and CONFIGURATION" on the display. Then press ENTER in
the desired mode. The display willl begin to scroll automatically
through available options.
Entering Diagnostics Menu for Lifestride Classic 9100, 9500
1. To find Software Version, press: 919-ENTER-RANDOM-FIT TEST. Program
lights come on. Display scrolls through to show control and logic.
2. To find Previous Wax Counts., press: 919-ENTER-FIT TEST. Program
lights come on. Display scrolls through to wax counts.
3. Previous Wax Counts must be entered manually. Diagnostic 919-ENTER.
Unplug wax pump and fire pump until count is correct.